| 000 | 03261nam a22004215i 4500 | ||
|---|---|---|---|
| 999 |
_c8000 _d8000 |
||
| 001 | 8000 | ||
| 003 | ES-MaUEC | ||
| 005 | 20200901170630.0 | ||
| 006 | a||||fo|||| 00| 0 | ||
| 007 | cr nn nnnaamaa | ||
| 008 | 200715s2020 si a o |||| 0|eng d | ||
| 020 | _a9789811537776 | ||
| 024 | 7 |
_a10.1007/978-981-15-3777-6 _2doi |
|
| 040 |
_aES-MaUEC _bspa _cES-MaUEC _dES-VaUE |
||
| 050 |
_aRD598.35 _b.S54 2020 EB |
||
| 245 | 1 | 0 |
_aSlender PCI : _bExtremely Minimally Invasive Percutaneous Coronary Intervention _cedited by Fuminobu Yoshimachi. |
| 250 | _aFirst edition | ||
| 264 | 1 |
_aSingapore _bSpringer Singapore _c2020 |
|
| 300 |
_a1 recurso en línea (X, 219 páginas) _b108 ilustraciones, 64 ilustraciones a color |
||
| 336 |
_2rdacontent _aTexto (visual) _btxt |
||
| 337 |
_2rdamedia _aelectrónico _bc |
||
| 338 |
_2rdacarrier _arecurso electrónico _bcr |
||
| 347 |
_aArchivo de texto _bPDF |
||
| 490 | 0 | _aMedicine (SpringerNature-11650) | |
| 490 | 0 | _aMedicine (R0) (SpringerNature-43714) | |
| 505 | 0 | _aBrief Overview of Slender Catheter -- Evidence of Slender PCI -- TRI to dTRI -- Distal Radial Approach / Distal Transradial Intervention -- Expectation for dTRI and Slender Catheter -- Slender Catheter Back-up -- Needling and Blood Snatching of Conventional Radial Approach & Distal Radial Approach -- Reduction of Radiation Exposure and Contrast Agent -- Semi-Comfpliant and Non-Compliant Slender Catheter -- FFR with a 4Fr Wide Lumen Diagnosis Catheter -- Catheter for 3Fr Diagnosis -- Sheathless of Slender in UK -- Sheathless of Slender in JP -- Slender PCI to Bifurcation Lesion -- Slender PCI to Calcified Lesion -- Slender PCI to ACS -- Slender CTO: Antegrade approach -- Slender CTO: Retrograde approach. | |
| 520 | _aThis book offers a valuable contribution to the field of minimally invasive coronary intervention, presenting the latest developments in slender catheters, their development and the related research findings. With the growing interest in trans-radial interventions (TRIs) and distal radial approach, "Slender PCI" has been popular in Japan. Although "Slender PCI" started with using a small diameter catheter of a 5Fr Guiding Catheter, recently it becomes a generic term for all minimally invasive catheter Interventions. "Slender PCI" not only makes less painful but also reduces exposure to radiation and contrast agents. In addition, the book highlights the distal radial approach, 5Fr guiding catheter for treating complex lesion, 4Fr guiding catheters, 3Fr diagnosis catheters. The authors share their experiences and know-how throughout, providing abundant illustrations to enhance readers' understanding. | ||
| 650 | 7 |
_2embne _913696 _aEnfermos cardíacos |
|
| 650 | 7 |
_2embne _96846 _aAparato circulatorio |
|
| 700 | 1 |
_aYoshimachi, Fuminobu _eeditor _4edt _4http://id.loc.gov/vocabulary/relators/edt |
|
| 710 | 2 | _aSpringerLink | |
| 776 | 0 | 8 |
_iPrinted edition: _z9789811537769 |
| 776 | 0 | 8 |
_iPrinted edition: _z9789811537783 |
| 776 | 0 | 8 |
_iPrinted edition: _z9789811537790 |
| 856 | 4 | 0 |
_uhttps://go.openathens.net/redirector/universidadeuropea.es?url=https://doi.org/10.1007/978-981-15-3777-6 _zAcceso a este recurso digital (usuarios Universidad Europea de Valencia) |
| 942 |
_2lcc _cLE |
||
| 998 | _db | ||