| 000 | 02592nam a22003615i 4500 | ||
|---|---|---|---|
| 999 |
_c8749 _d8749 |
||
| 001 | 8749 | ||
| 003 | ES-MaUEC | ||
| 005 | 20201203160845.0 | ||
| 006 | a||||fo|||| 00| 0 | ||
| 007 | cr nn 008mamaa | ||
| 008 | 150530s2015 gw | s |||| 0|eng d | ||
| 020 | _a9789811544668 | ||
| 024 |
_2doi _a10.1007/978-981-15-4466-8 |
||
| 040 |
_aES-MaUEC _bspa _dES-VaUE |
||
| 050 | 4 |
_aRC645.7 _b.B34 2020 EB |
|
| 100 |
_aBahk, Yong-Whee _9516354 |
||
| 245 | 1 | 0 |
_aImaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage _cby Yong-Whee Bahk |
| 250 | _a1st ed. 2020 | ||
| 260 |
_aSingapoure _bSpringer International Publishing _bImprint: Springer _c2020 |
||
| 300 |
_a1 recurso en línea (I-XVII, 146 páginas) _bilustraciones a color |
||
| 336 |
_aTexto (visual) _btxt _2rdacontent |
||
| 337 |
_aelectrónico _bc _2rdamedia |
||
| 338 |
_arecurso electrónico _bcr _2rdacarrier |
||
| 490 | 1 | _aMedicine (Springer-11650) | |
| 520 | _aThis excellently illustrated monograph summarizes the updated fresh information on the theoretical, practical, and rapidly extended facets of gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan (99mTc-GCPBS) to MRI, CR, and MDCT. Basically, 99mTc-GCPBS is able to precisely visualize and quantitate callused trabecular microfracture (CTMF) which is as little as 200 μm in size. The extended gamma correction images can very neatly demonstrate CTMF on MRI, conventional radiography (CR), and multidetector computed tomography (MDCT). Whenever appropriate, histological correlation is provided in conjunction with fine gamma corrected images. In this setting, ACDSee 10 gamma correction MRI and CR have been found to offer a highly useful option that deserves wider clinical interest. In practice, gamma correction MRI, CR, and MDCT can distinctly visualize CTMF so that CTMF can be precisely measured simply using an optic lens. By comparison, the naïve MRI, for example, shows CTMF which measures as big as 2 mm in size. Furthermore, 99mTc-GCPBS can now differentiate bone marrow edema from hemorrhage using the visuospatial mathematic method, which includes the ImageJ of the NIH. | ||
| 988 | _aEBOOK, EBSPRINGER | ||
| 856 | 4 | 0 |
_uhttps://go.openathens.net/redirector/universidadeuropea.es?url=http://dx.doi.org/10.1007/978-981-15-4466-8 _zAcceso a este recurso digital (usuarios Universidad Europea de Valencia) |
| 901 | _ai9783319178400 | ||
| 907 |
_a.b12910375 _b10-10-17 _c10-02-16 |
||
| 942 |
_2lcc _cLE |
||
| 945 |
_aRC394.H37 R565 2015 EB _g1 _ieBOOK _j0 _lmae _o- _pEUR0.00 _q- _r- _sb _t15 _u0 _v0 _w0 _x0 _y.i11578051 _z06-04-17 |
||
| 998 |
_db _feng _ggw _h0 |
||